Fire Alarm Systems –
Identify Fire Hazards in Time

Modern fire detection systems (FDS) detect fires early and independently report a direct call for help to the assisting agencies. They consist mainly of the fire panel, display and control of the fire detectors and alarms.

WATER EXTINGUISHING SYSTEMS

Water-based fire extinguishing systems
make up the largest share of the
extinguishing technology – in case of
sprinkler systems a simple and reliable
technology for decades.

GAS EXTINGUISHING SYSTEMS

The extinguishing effect of inert gases is
achieved by displacing the oxygen in the air.
Assets are protected by the slow response
that is typical of the inert gases CO2,
nitrogen and argon.

FIRE PROTECTION PRODUCTS

Basics as Fire Alarm Systems and
Gas Protection Systems or
innovations like cost-reduction
with automated system inspections
and the retrofit of Fire Dampers.

Quick warning using reliable fire detection technology to minimise the risk and damage

The latest fire detection technology makes it possible to detect fires before people are at risk or major damage is created. Highly sensitive sensors explore their environment for the first signs of a fire around the clock. Rosenbauer fire protection uses reliable sensors for the detection of smoke, heat or specific fumes in the fire detection systems. Your readiness to monitor fire detection technology is also not hindered even by adverse circumstances.

Operation of fire alarm systems

Automatic fire alarm system collects the signals from sensors and evaluates this information in a split second. If the limits are exceeded it sets extinguisher systems and door locking systems in motion and warns the fire brigade and extinguishing crews. This is all done automatically. The fire alarm system also monitors the connected sensors and alarms on a continuous basis for their operational readiness and reliably indicates faults before downtime occurs. To maintain operational readiness during power outages, fire panels usually have a battery-powered and feature-monitored emergency power supply.

APPLICATIONS FOR
FIRE ALARM SYSTEMS:

  • Fires that occur can be detected as early as possible with a fire alarm system.

  • Depending on the nature and programming of the fire alarm system, it is possible to perform actions such as notifying the fire brigade, announcements to evacuate buildings or starting connected sprinkler systems and gas extinguishing systems.

Options

Control Panel – In addition to the vendor-specific display and control facilities, the fire alarm system may also have a common display and control panel for the fire department. They can be informed by this means – using a device designed to DIN 14661 – quickly and securely about the system’s alarm condition. Detailed training is not required for the emergency services.

Key Storage – In case of fire in order to get quick and non-violent access to the property, fire alarm systems usually include fire brigade key storage. The property key contained in a vault is continuously monitored and is only accessible to the fire department in case of fire alarm.

Corresponding Standards for Fire Alarm Systems

There are no set nationwide standards for the technical and organizational fire protection. It is left to the states to formulate the requirements in detail. The person responsible for the planning and operation of the fire alarm system must therefore deal with the specific terms and provisions in detail. The requirements to be fulfilled vary greatly from application to application. A production facility for flammable gases shall comply with different fire safety regulations from those for a warehouse for hardware or a venue.

ADVANTAGES OF
FIRE ALARM SYSTEMS:

  • Commercial, sales and assembly areas

  • Hotels and Hostels

  • Hospitals

  • Shopping Centres

  • Banks, Insurance and Administration Buildings

  • Archives

  • Technology and Supply Centres

  • Operating Plants and Production Plants

FULL LINE DISTRIBUTOR
IN FIRE PROTECTION

Rosenbauer Fire Protection
provides the full line of
products and services
in the preventative
fire protection business.

BEST ADVICE AND
PROVEN DESIGN

Nearly three decades of
experience in planning and
designing fire protection
systems for all cases of
safety requirements.

IN-HOUSE ENGINEERING
AND ASSEMBLING

Supervision and construc-
tion according to various
safety standards by our
own engineers and
high qualified personnel.

RELIABLE SERVICE
AND MAINTENANCE

Continuous maintenance
by trustworthy partners
is the key to an
unimpeachable preventative
fire protection system.

Any questions to your own fire protection project?
Our experts are happy to help you further.

ALMOST THREE DECADES IN IMPLEMENTING FIRE PROTECTION SYSTEMS
AND STILL ON FIRE FOR IT.

WATER-BASED SYSTEMS

SPRINKLER SYSTEMS

This common type of water-based fire extinguishing system is reliable and easy to implement.

SPRAY DELUGE SYSTEMS

Deluge systems are the first choice in areas with a risk of rapidly spreading fires.

WATER SPRAY SYSTEMS

Water mist already exerts its effect on flames and smoke – for safety of people and assets.

GAS-BASED SYSTEMS

CO2 FIRE SYSTEMS

The gas-based extinguishing system with widest acceptance worldwide.

SAFETY INTEGRITY LEVEL 2

Systems certified for risk classes up to SIL 2 – an integral component in security concepts.

NOVEC 1230 SYSTEMS

Reliably and automatic protection for data processing and electronic control systems.

INNOVATIONS

ROSENBAUER SPRINKLER-APP

Get our Sprinkler-App! A useful tool to evaluate dimensions of sprinkler systems.

MASTERCONTROL

Subtantial reduction of operating costs with automated sprinkler system inspections.

FIRE DAMPER RETROFIT

Renovate the fire dampers by installing a low-pressure extinguisher system.